Home |
 |
Model |
GP1110 |
GP1115 |
GP1120 |
GP3110 |
GP3115 |
GP3120 |
GP3130 |
GP3140 |
Capacity |
10KVA |
15KVA |
20KVA |
10KVA |
15KVA |
20KVA |
30KVA |
40KVA |
Input |
Voltage |
220VAC±25% (Single phase 2 wires + G) |
380VAC±20% (Three phases 4 wires + G) |
Frequency |
50Hz ± 10% |
Power Factor |
0.8 ( 0.95 if UPS with filter ) |
Output |
Voltage |
220VAC±1% (steady state) |
220VAC±2% (steady state) |
Frequency |
Free synchronized to main (AC Power Mode);
50Hz±0.5%(Battery Mode) |
Power Factor |
0.8 (lagging) |
Wave Form |
Sine Wave |
Distortion |
£ 3% (linear load), £ 5% (non linear load) |
Crest Factor |
3:1 |
Transitory Voltage |
220VAC ± 4% |
220VAC ± 5% |
Type |
|
Battery |
12VDC Sealed lead acid battery, maintenance free |
Nominal Voltage |
192VDC (16 PCS) |
384VDC (32 PCS) |
Backup Time |
As per the request of customer |
Recharge Time |
7 ~ 10 hours up to 90% capacity |
Charge Current |
10~25A (Adjustable) |
Transfer Time |
0 ms ( AC to DC or DC to AC); < 4 ms
(Bypass to Inverter or Inverter to Bypass) |
LCD Display |
UPS work situation, AC power situation, Battery
situation, automatic turn to bypass, overload |
Overload Ability |
150% for 30 seconds, 125% for 10 minutes |
Protection |
Over Voltage, Under Voltage, Over Load,
Over Temperature, Short Circuit, Lightning Stroke etc. |
Alarm |
Over Temperature, Battery, Bypass, AC Power Abnormal,
Over Load, Over Voltage |
Noise ( 1 m distance) |
£55dB |
Communicate Interface |
RS232 (or RS422), SNMP Card (Optional), RJ45 |
Ambient |
Temperature |
0°C ~ 40 °C |
Humidity |
10% ~ 90% (no dewfall) |
Elevation |
< 2000m |
Size (mm) |
1140 x560 x800 |
N.W. (kg) |
140 |
175 |
225 |
181 |
235 |
285 |
320 |
355 |
EMC |
IEC62040-2, EN50091,GB9254 |
Ability of Antijamming |
IEC61000-4 |
Protection Degree |
IP20 |
|
| |
 |
| |
 |
| |
 |
| |
Low Frequency On line UPS
|
10KVA-20KVA (IP/OP:1 Ph/ 1Ph)
10KVA-40KVA (IP/OP:3 Ph/1Ph) |
| |
High Reliable
- Adopt twin change on line technology, sequester extraneous interference
- Favorable overload ability and protection
- Design with 100% unbalance protection
- 100% Non linear load ability
- IGBT, PWM inverter together with digital
logic power control technology
Super Safety
- The output isolate transformer can avoid the destruction of abnormal signal & lightning stroke
- With static bypass, repair bypass, battery maintain bypass
- Cold start
Smart
- Different loading have different use way. Single UPS, 1+1 or N+1 etc.
- Modular design, easy to repair
- Intelligent management for battery pack
Economic
- The efficiency of complete system more than 90%, it will be up to 95% or more if ECO mode
Easy Operation
- LCD display, it's easy to operate
Intelligent
- It can remote management and TVSS through the offered RS232()RS422, optional SNMP Card, RJ45 etc. communicate port
Appliance
- Data management equipment and system
- Automatic control systems
- Hospital
- Mini office system
- Telecommunication systems
- Bank
Technical Specifications:
|
|
| |
|
 |
|