Accessory
|
NETMATE II SNMP CARD |
| Function : |
|
1, Realtime UPS status monitoring: Develop the smart
UPS into a administrable device in the network. It can
be monitored and controled by SNMP network management
platform, Web browser and IP Power series monitor system.
2, Can monitor remote smart UPS in rack structure, computer
center and data center.
3, Powerful Web Server management module, users can
inquire UPS realtime status, manage basic information,
remote control UPS, configurate parameters and inquire
history data using WEB browser through any kind of operation
system. It can also send warning information through
Email to users and administrator.
4, Users can restrat the network device by distant control
to the UPS electricity output.
5, Complete UPS management and flexible parameter configuration
through Web Browser, NMS, IP Power, Telnet, SNMP or
Hyper-terminal.
6, Auto send event and alarm information through Email,
SNMP Trap and IP Power.
7, Protect and shutdown up to 250 network servers/ working
stations according to the fixed plan, to avoid data
loss and device damage caused by UPS battery exhaustion.
8, Manual (static state) and auto (dynamic) distribute
IP address.
9, Record UPS parameters periodically for statistic
analysis and failure diagnosis.
10, Interior TCP/IP network function module, supporting
SNMP,HTTP,Telnet,TCP,UDP,ARP,ICMP/DNS,SMTP,DHCP,SNTP,TFTP,PPP
network protocol.
11, Supporting standard UPS MIB (RFC1628) and PPC MIB
12, 10/100Mbps Ethernet self-adapt.
13, Simply realized hardware program network updating.
14, Multi-language extensible.
15, Interior PPP function module, including PPP server
and PPP client bidirectional function.
It supports access through Modem dailing to realize
remote login and monitor the UPS through phone line
when network is unavailable. It can also access long-distance
dail-up server and become a monitored node in the distant
network through telecommunication or mobile network.
16, Monitor and control single/three phase UPS for most
of the brands and can extend ambient temperature and
humidity monitoring.
17, Equiped with IP Power series UPS monitoring and
control software to centralized control remote UPS and
computer center environment. |
| Feature : |
|
1, Independent embeded system, without reling on
any other computers.
2, Can be simply installed into smart UPS interior extended
slot, incorporated with the UPS.
3, Simple and prompt for installation
4, Friendly user interface.
5, Realtime collect smart UPS and other devices'status
data and analyse, judge and manage the data. When the
device failed, it sends network warning to the monitor
Host and deliver device failure status and data.
6, Record history time and history data for a certain
period in the card.
7, Supporting heat insert and draw.
8, Interior system "watchdog" function to
support auto resume after system exceptional to assure
the system stability and reliability.
9, Interior long-life system clock, supporting user
manual collation and auto collation to keep up with
the local time.
10, Interior optimized SE communication protocol to
assure a full using of bandwidth and timeliness of data
collection.
11, Multi-configuration and management modes such as
Telnet, Terminal and Web Browser. Online updating supported,
to reduce the maintenance difficulty and improve efficiency.
12, Interior PPP service. User can select dail-up mode
as a standby communication method. When the Ethernet
failed, users can directly connect to exterior network
through phone line, CDMA or GPRS wireless dailing and
realize long-distance monitoring. Users can also directly
dailing through exterior network and connect to Netmate
II, to realize status inquiry and maintenance management
to the device.
13, Auto mail warning. When the device status reaches
to the user setting standard, Netmate II can auto send
mail warning and log collection table to the administrator
periodically.
|
| Specification : |
|
General description
CPU 32-bit ARM RISC-based 50 MH(CPU)
RAM 16M byte SDRAM
Flash ROM 2M byte Flash
Network connection 10/100Mbps high speed Ethernet self-adepted
Serial interface Two high-speed asynchronism RS232 connection
port to communicate with UPS and console; One RS422
connection port to extend devices
NMS supported HP OpenView,SUN Sunnet Manager,IBM NetView,Novell
NMS,Accton AccView,(Other SNMP Compliant NMSs)
Web browser supported Can be viewed through Internet
Explorer/Netscape or other compatible browsers
SNMP MIB Support MIB-II(RFC1213, RFC1315, RFC1316),UPS
MIB (RFC1628), PPC MIB
Network protocol TCP/IP, UDP, SNMP, Telnet, SNTP, HTTP,
SMTP, DHCP, DNS, TFTP, ARP, ICMP, PPP etc.
LED direction light Power, Status, Ready, LAN 10/100M
Link/Active
Input power(DC) 8volt ~ 15volt
Power consumption 5 volt maximum
Running environment Temperature: 0C ~ 70CHumidity: 10
~ 85%
Other setting Real time system clock
Multi-language English and Chinese simplified supported;
multi-language extensible
Hardware program updating Network updating
System security Offer filter system based on IP, and
user ID and password protection for system operation
and control
Quality guarantee 1 year exchange guarantee ,3 years
limited repair guarantee
|
| Benefit: |
|
1, Reduce the cost user spent on UPS power in the
computer network system and make more effective management
to the power system.
2, Round-the-clock real-time monitor and manage.
3, Make the management and maintenance work easier for
users.
4, Improve the stability and reliability of the UPS
power and the safty of the computer network.
5, User can get timely information about the failure
of UPS power system.
6, Make sure the data in the user server safer.
7, Centralized network monitoring the ambient environment
of the operation center , such as temperature and humidity,
at the same time of UPS monitoring.
|
| Application : |
|
Apply to remote monitoring UPS in network rack frame,
computer center and data center, and its power supply
and ambient environment. The administrator can save
their trip patrolling the distant computer centers.
When UPS power supply failed, the Network servers and
workstations will auto shutdown in turn safely, to provide
data loss and hardware damage, which cost an unredeemable
loss.
Get to know the failure information and warning information
of the UPS and its ambient by simple communication methods
( mobile phone, Email, phone line, network etc.), making
the administrators be able to master the problem with
effective solutions before it affect the system usability. |
|
|