NETMATE II SNMP CARD
 
  Products
 
 


Accessory


  • NETMATE II SNMP CARD
  • NETMATE II SNMP CARD

     Function :
    1, Realtime UPS status monitoring: Develop the smart UPS into a administrable device in the network. It can be monitored and controled by SNMP network management platform, Web browser and IP Power series monitor system.
    2, Can monitor remote smart UPS in rack structure, computer center and data center.
    3, Powerful Web Server management module, users can inquire UPS realtime status, manage basic information, remote control UPS, configurate parameters and inquire history data using WEB browser through any kind of operation system. It can also send warning information through Email to users and administrator.
    4, Users can restrat the network device by distant control to the UPS electricity output.
    5, Complete UPS management and flexible parameter configuration through Web Browser, NMS, IP Power, Telnet, SNMP or Hyper-terminal.
    6, Auto send event and alarm information through Email, SNMP Trap and IP Power.
    7, Protect and shutdown up to 250 network servers/ working stations according to the fixed plan, to avoid data loss and device damage caused by UPS battery exhaustion.
    8, Manual (static state) and auto (dynamic) distribute IP address.
    9, Record UPS parameters periodically for statistic analysis and failure diagnosis.
    10, Interior TCP/IP network function module, supporting SNMP,HTTP,Telnet,TCP,UDP,ARP,ICMP/DNS,SMTP,DHCP,SNTP,TFTP,PPP network protocol.
    11, Supporting standard UPS MIB (RFC1628) and PPC MIB
    12, 10/100Mbps Ethernet self-adapt.
    13, Simply realized hardware program network updating.
    14, Multi-language extensible.
    15, Interior PPP function module, including PPP server and PPP client bidirectional function.
    It supports access through Modem dailing to realize remote login and monitor the UPS through phone line when network is unavailable. It can also access long-distance dail-up server and become a monitored node in the distant network through telecommunication or mobile network.
    16, Monitor and control single/three phase UPS for most of the brands and can extend ambient temperature and humidity monitoring.
    17, Equiped with IP Power series UPS monitoring and control software to centralized control remote UPS and computer center environment.
     Feature :
    1, Independent embeded system, without reling on any other computers.
    2, Can be simply installed into smart UPS interior extended slot, incorporated with the UPS.
    3, Simple and prompt for installation
    4, Friendly user interface.
    5, Realtime collect smart UPS and other devices'status data and analyse, judge and manage the data. When the device failed, it sends network warning to the monitor Host and deliver device failure status and data.
    6, Record history time and history data for a certain period in the card.
    7, Supporting heat insert and draw.
    8, Interior system "watchdog" function to support auto resume after system exceptional to assure the system stability and reliability.
    9, Interior long-life system clock, supporting user manual collation and auto collation to keep up with the local time.
    10, Interior optimized SE communication protocol to assure a full using of bandwidth and timeliness of data collection.
    11, Multi-configuration and management modes such as Telnet, Terminal and Web Browser. Online updating supported, to reduce the maintenance difficulty and improve efficiency.
    12, Interior PPP service. User can select dail-up mode as a standby communication method. When the Ethernet failed, users can directly connect to exterior network through phone line, CDMA or GPRS wireless dailing and realize long-distance monitoring. Users can also directly dailing through exterior network and connect to Netmate II, to realize status inquiry and maintenance management to the device.
    13, Auto mail warning. When the device status reaches to the user setting standard, Netmate II can auto send mail warning and log collection table to the administrator periodically.


     Specification :
    General description
    CPU 32-bit ARM RISC-based 50 MH(CPU)
    RAM 16M byte SDRAM
    Flash ROM 2M byte Flash
    Network connection 10/100Mbps high speed Ethernet self-adepted
    Serial interface Two high-speed asynchronism RS232 connection port to communicate with UPS and console; One RS422 connection port to extend devices
    NMS supported HP OpenView,SUN Sunnet Manager,IBM NetView,Novell NMS,Accton AccView,(Other SNMP Compliant NMSs)
    Web browser supported Can be viewed through Internet Explorer/Netscape or other compatible browsers
    SNMP MIB Support MIB-II(RFC1213, RFC1315, RFC1316),UPS MIB (RFC1628), PPC MIB
    Network protocol TCP/IP, UDP, SNMP, Telnet, SNTP, HTTP, SMTP, DHCP, DNS, TFTP, ARP, ICMP, PPP etc.
    LED direction light Power, Status, Ready, LAN 10/100M Link/Active
    Input power(DC) 8volt ~ 15volt
    Power consumption 5 volt maximum
    Running environment Temperature: 0C ~ 70CHumidity: 10 ~ 85%
    Other setting Real time system clock
    Multi-language English and Chinese simplified supported; multi-language extensible
    Hardware program updating Network updating
    System security Offer filter system based on IP, and user ID and password protection for system operation and control
    Quality guarantee 1 year exchange guarantee ,3 years limited repair guarantee

    Benefit:
    1, Reduce the cost user spent on UPS power in the computer network system and make more effective management to the power system.
    2, Round-the-clock real-time monitor and manage.
    3, Make the management and maintenance work easier for users.
    4, Improve the stability and reliability of the UPS power and the safty of the computer network.
    5, User can get timely information about the failure of UPS power system.
    6, Make sure the data in the user server safer.
    7, Centralized network monitoring the ambient environment of the operation center , such as temperature and humidity, at the same time of UPS monitoring.

     Application :
    Apply to remote monitoring UPS in network rack frame, computer center and data center, and its power supply and ambient environment. The administrator can save their trip patrolling the distant computer centers.

    When UPS power supply failed, the Network servers and workstations will auto shutdown in turn safely, to provide data loss and hardware damage, which cost an unredeemable loss.

    Get to know the failure information and warning information of the UPS and its ambient by simple communication methods ( mobile phone, Email, phone line, network etc.), making the administrators be able to master the problem with effective solutions before it affect the system usability.


     
      COPYRIGHT @ SHENZHEN SORO ELECTRONICS CO.,LTD  
      TEL : 86-755-33683650 3366683651 FAX:86-755-33683653  
      E-MAIL : sales@soroups.com MSN soroups@hotmail.com  
      ADD : TianFuAn Industrial Zone, xi xiang Bao An District ,
                Shen Zhen ,Guangdong,P.R.China P.C. 518102